Antiphospholipid syndrome

Record number: 
1099
Adverse Occurrence type: 
MPHO Type: 
Estimated frequency: 
uncommon
Time to detection: 
Years
Alerting signals, symptoms, evidence of occurrence: 
Cerebrovascular thrombosis
Demonstration of imputability or root cause: 
Autoantibodies identical to donor (anticardiolipin antibodies, ANA, lupus anticoagulant);
Suggest references: 
Ritchie, D.S., et al, Passive donor-to-recipient transfer of antiphospholipid syndrome following allogeneic stem-cell transplantation. Am J Hematol. 2005 Aug;79(4):299-302