Status:
Ready to upload
Record number:
1263
Adverse Occurrence type:
MPHO Type:
Estimated frequency:
Case Report
Time to detection:
85 minutes
Alerting signals, symptoms, evidence of occurrence:
Following the transfusion, patient had bilirubin and urobilinogen in his urine and a fall in haemoglobin of nearly 2 g dL (-1).
Demonstration of imputability or root cause:
Clinical and serology results.
Imputability grade:
3 Definite/Certain/Proven
Groups audience:
Keywords:
Suggest new keywords:
anti-Wr, Diego
Suggest references:
Cherian. G., Search, S., Thomas, E., Poole, J., Davies, S.V. and Massey, E. (2007). An acute haemolytic transfusion reaction caused by anti-Wr. Transfus Med 17(4):312-314.
Expert comments for publication: