Record number:
965
Adverse Occurrence type:
MPHO Type:
Estimated frequency:
Never reported before to this vigilance programme
Alerting signals, symptoms, evidence of occurrence:
Hemolysis of donor erythrocytes, shivering, anuria and renal failure of patient
Demonstration of imputability or root cause:
One of the recipients of a double cord blood transplant was major ABO incompatible. Patient died 1 month later due to a non related infection