Record number:
871
Adverse Occurrence type:
MPHO Type:
Alerting signals, symptoms, evidence of occurrence:
Early/late postoperative oliguria, generalized edema, abnormal urine electrolytes, elevated creatinine/BUN
Demonstration of imputability or root cause:
Possible consequence of any surgery. Not a normal finding prior to donation.
Suggest references:
AAA