Antibody-mediated hemolysis

Status: 
Ready to upload
Record number: 
1765
Adverse Occurrence type: 
MPHO Type: 
Estimated frequency: 
Infrequent, not rare
Time to detection: 
Immediate to within a few days of transfusion of IVIg
Alerting signals, symptoms, evidence of occurrence: 
Hemolysis, dropping hct/hgb
Demonstration of imputability or root cause: 
+DAT with eluate having same specificity as found in IVIG product
Imputability grade: 
3 Definite/Certain/Proven
Groups audience: 
Suggest new keywords: 
Hemolysis
IVIG
Suggest references: 
http://www.ncbi.nlm.nih.gov/pubmed/26174897
Note: 
This article can be combined or linked with record 1764. All of them are under the same category of hemolysis following IVIG transfusion
Expert comments for publication: 
Review article on multiple pathophysiological pathways towards hemolysis after IVIG transfusion