Hemorrhage requiring transfusion within 12 weeks of ART cycle initiation

Status: 
Ready to upload
Record number: 
1596
Adverse Occurrence type: 
MPHO Type: 
Estimated frequency: 
2,5/10.000 started ART cycles, calculated on 1.133.206 cycles in USA from 2000 to 2011.
Time to detection: 
minutes - hours
Alerting signals, symptoms, evidence of occurrence: 
Acute anemia, tachycardia, low blood pressure, shock, few minutes or hours since ovarian puncture for ovum retrieval.
Demonstration of imputability or root cause: 
Vasal or ovarian lesion during ovarian puncture.
Imputability grade: 
3 Definite/Certain/Proven
Groups audience: 
Reference attachment: 
Suggest references: 
Kawwass JF, Kissin DM, et al. Safety of assisted reproductive technology in the United States, 2000-2011. JAMA. 2015 Jan 6;313(1):88-90
Expert comments for publication: 
It is a well controllable complication, easily ascertainable with ultrasound scan, frequently autolimiting. Only in rare cases laparoscopy or laparotomy are necessary to repair the lesion.