Status:
Ready to upload
Record number:
1267
Adverse Occurrence type:
MPHO Type:
Estimated frequency:
Case report
Time to detection:
minutes
Alerting signals, symptoms, evidence of occurrence:
Fever, chills, dyspnea, bilateral loin pain.
Demonstration of imputability or root cause:
Clinical and serology results, hemoglobinuria.
Imputability grade:
2 Probable
Groups audience:
Keywords:
Suggest references:
Pradhan, D. and Chaudhary, R. (1999). Acute intravascular haemolytic transfusion reaction due to anti-c undetected by conventional pretransfusion cross-matching tests. Am J Hematol 61(1):82-83
Expert comments for publication:
A striking finding was the discordancy between strongly positive antibody screen using polyethylene glycol antiglobulin test (PEG-AGT) but not with saline or enzyme treated crossmatches.